Version 1.0.49.0

- Maxim version added

Version 1.0.50.0

- PD plotter added
- MAXREFDES79 firmware upgrde mode added

Version 1.0.50.1

- PD plotter changes

Version 1.0.52

- Master finder (on TCP/IP network)

Version 1.0.53

- Additional exception handling added to the Master finder

Version 1.0.54

- Bugfixes on Master finder

Version 1.0.55

- Fixed color palette and PD input field. Reported by MAXIM

Version 1.0.56

- Direct Page parameter 1/2 read/write issue solved (requires new master firmware)

Version 1.0.57

- Mutex inserted not to miss to send buffered outgoing telegrams

Version 1.1.11

- Conversion issue with the 32 bit length PD out solved

Version 1.1.12

- Subindex access supported checknig feature is implemented.
- Issue with the IODD's without serial number issue corrected.
- Issue with the IODD's without PD in issue corrected.

Version 1.1.13

- Issue with the writing of single value of a standard parameter corrected.

Version 1.1.14

- Master event handling has been added.

Version 1.1.15

- Issue with getting the current serial number (which can cause crash) fixed.

Version 1.1.16

- It shows the Vcom identifier
- Finds automaticaly the connected TEConcept 1 port Master
- Selects automaticaly the connected Master port number
- Let to set the AARDVARK polarity and phase

Version 1.1.17

- AARDVARK, TCP/IP port issue from the version 1.1.16 solved.

Version 1.1.18

- AARDVARK settings are saved.
- AARDVARK communication modification, CT waits after the second byte when sending the request telegram.

Version 1.1.21

- PD out GUI elemnts were changed and some bugs were corrected with the PD out handling
- Freescalse Master FW upgrade functionality has been added
- Rockwell Master FW upgrade functionality has been added
- Read Event telegram and Get ISDU answer telegram have been modified -> adjusted to the specification

Version 1.1.22

- Actual and set PD lengths are checked. If they differ, the CT settings are sent to the Master.

Version 2.0

- PortTabPage user control project is added to the solution, all the port related function is moved here.
- Docking functionallity implemented.
- Objectlistview component are used to visualize the data from now.
- Duplicated codes removed.
- Issues fixed regarding the new GUI.
- New build order and assembly versioning.
- Data storage handling implemented.
- Settings form is added, for now it only enables to change the process data streams.

Version 2.1.6226.27420
 - Simple firmware revision number is used instead of the length FW version for the TEC 1P Master.
 - The way of selecting the proper FTDI connection for the MAXREFDES145_A is improved.

Version 2.1.6288.19446
 - DirectParameterOverlay issue fixed.

Version 2.2.6295
 - Full support for the IDrectParameterOverlay and StdDirectParameterRef

Version 2.2.6299
 - Reimplemented menu structure (Menu hierarchy fully supported).
 - DataStorage error with the last index is fixed.
 - The tool doesn't search for the process data unit and gradient, offset is ProcessDataRef is not defined in the MenuCollection.

 Version 2.2.6306
 - Block parametrisation issue fixes (Master and CT)
 - SMC issue fixes.
 - Data Storage refresh after block parameter download.

 Version 2.3.6311
 - DS activation state change when the port is operating.
 - DS Validity flag shown.
 - Port configuration download.

 Version 2.3.6326
 - Menu hierarchy issue with the submenus are fixed.

 Version 3.0.6413 (Major changes)
 - Control Tool project is restructured.
 - IODD parser is completely changed.
 - Complete IODD handling is changed.
 - Minor UI changes (Advanced port settings).
 - Direct parameter overlay handling is implemented.

Version 3.1.6452
 - New data storage states, for each state the DSActivation configuration is set.
 - Action logging mechanism is implemented.
 - PEAK-PCAN-USB interface is implemented.
 - Animations are removed - is was a huge overhead.
 - Adnvanced Port configuration is implemented.
 - Menu structure update is issued at the and of the ISDU sequence.
 - Conditional parameters of the device are now read automatically when the device is waked up.

Version 3.2.6513:
 - Logical true value for the Boolean type is now send as 0xff accoring to the specification.
 - Minor issue typeo and apperance fixes.

 Version 3.4:
 - IODD finder integration.
 - BLOB last without padding bytes.
 - DUOmetric issue fix for complex byte array inserting.

 Version 3.5.6708:
 - Aardwark / FTDI interface support checking.
 - Multiple FTDI interface selection.
 - EMC Test mode support (LOOPBACK).

 Version 3.7.6838 (2018.09.21)
 - Finished BLOB transfer support
 - Arrow master firmware update implementation.

 Version 3.8.6927 (2018.12.19)
 - MAXREFDES79 issue fix.
 - Event handling issue fixed.
 - FTDI dll added to the installer.

Version 3.9.7454:
 - FW Download is not supported when target mode is not set to SCAN mode.
 - UI improvements.

Version 3.9.7475:
 - The issue with empty productId is fixed in this version.

Version 3.10.7689:
 - Plotting boolean values are enabled.
 - SPI clock frequency is reduced to 5MHz.